AccuPrep MPS
Gel Permeation Chromatography
Cleanup System

A revolution in GPC Cleanup system design, the AccuPrep MPSTM combines flexibility and cutting-edge features in a smaller package.

- Sample capacity increased to 120 positions
with extended tray

- Standard pressure rating of 2500 psig

- Optional on-board Windows-based PC
eliminates need for a desktop computer

- Direct Inject, loop-overfill and partial-loop fill
injection available on one platform

The AccuPrep MPS for GPC Cleanup performs cleanup of a wide range of sample matrices including foods, tissues, grains, plants and environmental samples such as soil, sludge, and hazardous waste for EPA (SW-846 Method 3640A), CLP, FDA, USDA and USDI analysis.

The new AccuPrep MPS has the core features that previous AccuPrep systems have been known for: Solvent Level Sensing warns when solvent is low and pauses operation if the level is not replenished; Probe Tracking feature minimizes probe contact with the sample and increases rinsing efficiency; and Septum Piercing allows sample and collect vials to be sealed, ensuring the integrity of the sample.

CLICK BELOW FOR MORE INFORMATION
FEATURES / SPECIFICIATIONS
KEY FEATURES

-SEPTUM PIERCING
-PROBE TRACKING
-SOLVENT LEVEL SENSOR
-UPS POWER WATCHDOG
-USES DISPOSABLE, SEALABLE SAMPLE VIALS
-FLOW-RATE CALIBRATION
-BYPASS OR 5-COLUMN SELECTOR
-COLUMN HEATER CONTROL
-AUTOMATED SOLVENT SWITCHING
-SOLVENT FLOW RAMPING
-MULTIPLE INJECTIONS

TRAY OPTIONS

STANDARD
-72 Position, 25x200 mm vials
-42 Postition, 38x200 mm vials
-Boiling Flasks, 250 mL, 24 Position
-TurboVap Tubes, 200 mL, 25 Position
-Bottles, 125mL, 25 Position
-RapidVap Tubes, 500mL, 12 Position

EXTENDED TRAY
-120 Position, 25x200 mm vials
-70 Position, 38x200 mm vials
-Boiling Flasks, 250 mL, 24 Position
-TurboVap Tubes, 200 mL, 40 Position
-RapidVap Tubes, 500 mL, 20 Position

SPECIALTY TRAYS AVAILABLE UPON REQUEST

SOFTWARE FEATURES

-WINDOWS-BASED PC SOFTWARE
-USE DESKTOP OR ON-BOARD PC
-PRIORITY SAMPLE DESIGNATION
-PROGRAMMABLE SOLVENT ADDITION FOR VIAL RINSING
-CLP-DRIVEN REPORTS
-SAMPLE REPORTS
-CALIBRATION REPORTS
-SEQUENCE REPORTS
-PEAK FINDING
-AUTO RESOLUTION CALCULATION

DETECTOR (Optional)
FIXED WAVELENGTH AVAILABLE WITH A 254nm OR 280nm LAMP
COMPATIBLE COLUMNS

TRADITIONAL GLASS COLUMN
EXPRESS™ PERFORMANCE COLUMN
ENVIROSEP-ABC® COLUMN

SPECIALTY CONFIGURATIONS
SAVE MONEY BY USING A DETECTOR YOU ALREADY OWN. CALL TO VERIFY COMPATIBILITY

 